Mycoplasma Pneumoniae (MP)

Tlhaloso e Khutšoanyane:

Sehlahisoa sena se sebelisoa bakeng sa tlhahlobo ea in vitro ea boleng ba Mycoplasma pneumoniae (MP) nucleic acid lisampoleng tsa sekhohlela sa motho le oropharyngeal swab.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-RT024 Mycoplasma Pneumoniae (MP) ea Nucleic Acid Detection Kit(Fluorescence PCR)

Epidemiology

Mycoplasma pneumoniae (MP) ke mofuta oa kokoana-hloko e nyenyane ka ho fetisisa ea prokaryotic, e pakeng tsa baktheria le kokoana-hloko, e nang le sebopeho sa lisele empa e se na lerako la sele.MP haholo e baka tšoaetso ea phefumoloho ea batho, haholo-holo ho bana le bacha.E ka baka pneumonia ea mycoplasma ea motho, tšoaetso ea matšoafo ea bana le pneumonia e sa tloaelehang.Lipontšo tsa kliniki li fapane, boholo ba tsona ke khohlela e matla, feberu, serame, hlooho e bohloko, 'metso.Tšoaetso e ka holimo ea matšoafo le pneumonia ea bronchial ke tsona tse atileng haholo.Bakuli ba bang ba ka hlaha ho tloha ho ts'oaetso e phahameng ea phefumoloho ho isa ho pneumonia e matla, khatello e matla ea ho hema le lefu le ka hlaha.

Channel

FAM Mycoplasma pneumoniae
VIC/HEX

Taolo ea ka hare

Tekheniki Parameters

Polokelo

≤-18℃

Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala Sputum, Oropharyngeal swab
Ct ≤38
CV ≤5.0%
LoD 200 likopi / mL
Tse khethehileng a) Cross reactivity: ha ho na cross reactivity with Ureaplasma urealyticum, Mycoplasma genitalium, Mycoplasma hominis, Streptococcus pneumoniae, Chlamydia pneumoniae, Haemophilus influenzae, Klebsiella pneumoniae, Staphylococcus aureus, Mycobacteriuinodocucoccus aphilamonaella, Lefulococcus aureus, Mycobacteriuinodocucoccus aphilamonaella bacter baumannii, kokoana-hloko ea Influenza A , kokoana-hloko ea Influenza B, kokoana-hloko ea Parainfluenza I/II/III/IV, Rhinovirus, Adenovirus, Human metapneumovirus, Respiratory syncytial virus le human genomic nucleic acid.

b) Bokhoni ba ho thibela tšitiso: ha ho na tšitiso ha lintho tse sitisang li lekoa ka lintlha tse latelang: hemoglobin (50mg/L), bilirubin (20mg/dL), mucin (60mg/mL), 10% (v/v) mali a motho, levofloxacin (10μg/mL), moxifloxacin (0.1g/L), gemifloxacin (80μg/mL), azithromycin (1mg/mL), clarithromycin (125μg/mL), erythromycin (0.5g/L), doxycycline (50mg/mL), doxycycline (50mg/mL), erythromycin (0.5g/L), doxycycline (50mg/mL), /L), minocycline (0.1g/L).

Lisebelisoa tse sebetsang Lisebelisoa tsa Biosystems 7500 tsa Nako ea 'Nete ea PCR

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR

SLAN-96P ea Nako ea Sebele PCR Systems (Hongshi Medical Technology Co., Ltd.)

LightCycler®Sistimi ea 480 ea Nako ea 'Nete ea PCR

LineGene 9600 Plus Nako ea 'Nete ea PCR Detection System (FQD-96A, theknoloji ea Hangzhou Bioer)

MA-6000 Nako ea 'Nete ea Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

(1) Mohlala oa sekhohlela

Sehlahisoa se khothalelitsoeng: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (e ka sebelisoang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Eketsa 200µL ea letsoai le tloaelehileng ho pula e lokiselitsoeng.Ho ntšoa ka mor'a moo ho lokela ho etsoa ho latela litaelo tsa tšebeliso.Bophahamo bo khothaletsoang ba tlhahiso ke 80µL. Sehlahisoa se khothalelitsoeng sa ho hula: Nucleic Acid Extraction kapa Purification Reagent (YDP315-R).Ho ntšoa ho lokela ho etsoa ka thata ho latela litaelo tsa tšebeliso.Molumo o khothaletsoang oa elution ke 60µL.

(2) Oropharyngeal swab

Sehlahisoa se khothalelitsoeng: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (e ka sebelisoang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ho ntšoa ho lokela ho etsoa ho ea ka taelo ea tšebeliso.Bolumo e khothaletsoang ea ho ntšoa ea sampole ke 200µL, 'me molumo o khothaletsoang oa elution ke 80µL. Recommended extraction reagent: QIAamp Viral RNA Mini Kit (52904) kapa Nucleic Acid Extraction or Purification Reagent (YDP315-R).Ho ntšoa ho lokela ho etsoa ka thata ho latela litaelo tsa tšebeliso.Molumo o khothaletsoang oa ho ntša sampole ke 140µL, 'me bophahamo ba modumo o khothaletsoang ke 60µL.


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona