Mycoplasma Hominis Nucleic Acid
Lebitso la sehlahisoa
HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Mafu a tšoaetsanoang ka thobalano (STDs) e ntse e le e 'ngoe ea litšokelo tsa bohlokoa ho ts'ireletso ea bophelo bo botle ba sechaba lefatšeng ka bophara, e ka lebisang ho nyopa, tsoalo ea lesea pele ho nako, tumorigenesis le mathata a fapaneng a tebileng.Mycoplasma hominis e teng ka har'a pampiri ea genitourinary mme e ka baka likarabo tsa ho ruruha ka har'a pampiri ea genitourinary.Tšoaetso ea MH ea genitourinary tract e ka baka mafu a kang a non-gonococcal urethritis, epididymitis, joalo-joalo, le har'a basali, e leng se ka bakang ho ruruha ha mokhoa oa ho ikatisa o jalang o lebisitsoe molomong oa molomo.Ka nako e ts'oanang, bothata bo tloaelehileng ba tšoaetso ea MH ke salpingitis, 'me palo e nyenyane ea bakuli e ka' na ea e-ba le endometritis le lefu la ho ruruha ha pelvic.
Channel
FAM | Sepheo sa MH |
VIC(HEX) | Taolo ea ka hare |
Tekheniki Parameters
Polokelo | Mokelikeli: ≤-18℃ Lefifing |
Shelf-bophelo | Likhoeli tse 12 |
Mofuta oa Mohlala | secretions urethral, secretions cervical |
Ct | ≤38 |
CV | 5.0% |
LoD | 1000Likopi/mL |
Tse khethehileng | Ha ho na cross-reactivity le likokoana-hloko tse ling tsa tšoaetso ea STD, tse ka ntle ho sebaka sa ho lemoha, 'me ha ho na cross-reactivity le chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus mofuta oa 1, herpes simplex virus mofuta oa 2. , joalo-joalo. |
Lisebelisoa tse sebetsang | E ka tsamaisana le lisebelisoa tsa PCR tsa fluorescent tse fumanehang 'marakeng. Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Nako ea 'Nete ea PCR Systems Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P Sesebelisoa sa PCR sa LightCycler®480 Real-Time LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi MA-6000 Real-Nako Quantitative Thermal Cycler Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96 BioRad CFX Opus 96 Real-Nako PCR System |
Phallo ea Mosebetsi
Khetho ea 1.
Sehlahisoa sa ho ntša se khothalelitsoeng: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8).Ho ntšoa ho lokela ho etsoa ka thata ho latela litaelo.
Khetho ea 2.
Sehlahisoa se khothalelitsoeng: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (e ka sebelisoang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ho ntšoa ho lokela ho etsoa ka thata ho latela litaelo.Molumo o khothaletsoang oa elution e lokela ho ba 80 μL.
Khetho ea 3.
Sehlahisoa se khothalelitsoeng sa ho ntša: Nucleic Acid Extraction or Purification Reagent (YDP302) ke Tiangen Biotech (Beijing) Co., Ltd.