Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid

Tlhaloso e Khutšoanyane:

Setsi sena se loketse ho lemoha boleng ba likokoana-hloko tse tloaelehileng ho tšoaetso ea urogenital in vitro, ho akarelletsa le Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), le Neisseria gonorrhoeae (NG).


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la Sehlahiswa

HWTS-UR019A-Freeze-Omisitsoeng Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid Detection Kit (Fluorescence PCR)

HWTS-UR019D-Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Mafu a tšoaetsanoang ka thobalano (STD) e ntse e le e 'ngoe ea litšokelo tse kholo ho ts'ireletseho ea bophelo bo botle ba sechaba lefatšeng ka bophara, e ka lebisang ho nyopa, tsoalo ea lesea pele ho nako, tumorigenesis le mathata a fapaneng a tebileng. Ho na le mefuta e mengata ea mafu a likobo, ho kenyelletsa le mefuta e kang baktheria, livaerase, chlamydia, mycoplasma le spirochetes, joalo-joalo, 'me mefuta e tloaelehileng ke Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum, Herpes simplex virus type 1, herpes simplex virus type 2, Mycoplasma, Mycoplasma, Mycoplasma jj.

Channel

FAM Chlamydia trachomatis (CT)
VIC(HEX) Ureaplasma urealyticum (UU)
ROX Neisseria gonorrhoeae (NG)
CY5 Taolo ea ka hare

Tekheniki Parameters

Polokelo Mokelikeli: ≤-18℃ Lefifing; Lyophilized: ≤30℃ Lefifing
Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala Li-secretions tsa urethral, ​​li-secretions tsa popelo
Ct ≤38
CV 5.0%
LoD Mokelikeli: 400 Likopi / mL; Lyophilized: Likopi tse 400/mL
Tse khethehileng Ha ho na cross-reactivity bakeng sa ho lemoha likokoana-hloko tse ling tse tšoaelitsoeng ke STD, tse kang Treponema pallidum, joalo-joalo.
Lisebelisoa tse sebetsang

E ka tsamaisana le lisebelisoa tsa PCR tsa fluorescent tse fumanehang 'marakeng.

Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR System

QuantStudio® 5 ea Nako ea 'Nete ea PCR Systems

Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P

Sesebelisoa sa PCR sa LightCycler®480 Real-Time

LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi

MA-6000 Real-Nako Quantitative Thermal Cycler

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi