Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid

Tlhaloso e Khutšoanyane:

Setsi sena se loketse ho lemoha boleng ba likokoana-hloko tse tloaelehileng ho tšoaetso ea urogenital in vitro, ho akarelletsa le Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), le Neisseria gonorrhoeae (NG).


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la Sehlahiswa

HWTS-UR019A-Freeze-Omisitsoeng Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid Detection Kit (Fluorescence PCR)

HWTS-UR019D-Chlamydia Trachomatis, Ureaplasma Urealyticum le Neisseria Gonorrhoeae Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Mafu a tšoaetsanoang ka thobalano (STD) e ntse e le e 'ngoe ea litšokelo tse kholo ho ts'ireletso ea bophelo bo botle ba sechaba lefatšeng ka bophara, e ka lebisang ho nyopa, tsoalo ea lesea pele ho nako, tumorigenesis le mathata a fapaneng a tebileng.Ho na le mefuta e mengata ea mafu a likobo, ho kenyelletsa le mefuta e kang libaktheria, livaerase, chlamydia, mycoplasma le spirochetes, joalo-joalo, 'me mefuta e tloaelehileng ke Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum, Herpes simplex virus type 1, herpes simplex virus type 2, Mycoplasma hominis, Mycoplasma genitalium, joalo-joalo.

Channel

FAM Chlamydia trachomatis (CT)
VIC(HEX) Ureaplasma urealyticum (UU)
ROX Neisseria gonorrhoeae (NG)
CY5 Taolo ea ka hare

Tekheniki Parameters

Polokelo Mokelikeli: ≤-18℃ Lefifing;Lyophilized: ≤30℃ Lefifing
Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala Li-secretions tsa urethral, ​​li-secretions tsa popelo
Ct ≤38
CV 5.0%
LoD Mokelikeli: 400 Likopi / mL;Lyophilized: Likopi tse 400/mL
Tse khethehileng Ha ho na cross-reactivity bakeng sa ho lemoha likokoana-hloko tse ling tse tšoaelitsoeng ke STD, tse kang Treponema pallidum, joalo-joalo.
Lisebelisoa tse sebetsang

E ka tsamaisana le lisebelisoa tsa PCR tsa fluorescent tse fumanehang 'marakeng.

Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR System

QuantStudio® 5 ea Nako ea 'Nete ea PCR Systems

Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P

Sesebelisoa sa PCR sa LightCycler®480 Real-Time

LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi

MA-6000 Real-Nako Quantitative Thermal Cycler

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

a5e2212230f05592defb9076942a7d1


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona