Mefuta e 28 ea Vaerase ea Papilloma ea Motho e Kotsing e Phahameng (Type ea 16/18) Nucleic Acid
Lebitso la sehlahisoa
HWTS-CC006A-28 Mefuta ea Vaerase ea Papilloma ea Motho e Kotsing e Holimo (Typing ea 16/18) Kit ea ho Fumana Asiti ea Nucleic (Fluorescence PCR)
Thuto ea mafu a seoa
Kankere ea molomo oa popelo ke e 'ngoe ea lihlahala tse kotsi tse atileng haholo tsa tsela ea ho ikatisa ea basali. Lithuto li bontšitse hore tšoaetso e sa khaotseng ea HPV le tšoaetso e mengata ke e 'ngoe ea lisosa tse ka sehloohong tsa kankere ea molomo oa popelo. Hona joale, mekhoa ea phekolo e sebetsang e tsebahalang e ntse e haella bakeng sa kankere ea molomo oa popelo e bakoang ke HPV, kahoo ho sibolloa le ho thibeloa ha tšoaetso ea molomo oa popelo e bakoang ke HPV ke senotlolo sa ho thibela kankere ea molomo oa popelo. Ho bohlokoa haholo ho theha tlhahlobo e bonolo, e tobileng le e potlakileng ea tlhahlobo ea etiology bakeng sa tlhahlobo ea kliniki le kalafo ea kankere ea molomo oa popelo.
Mokero
| Motsoako oa Karabelo | Mokero | Mofuta |
| PCR-Mix1 | FAM | 18 |
| VIC(HEX) | 16 | |
| ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
| CY5 | Taolo ea Ka Hare | |
| PCR-Mix2 | FAM | 6, 11, 54, 83 |
| VIC(HEX) | 26, 44, 61, 81 | |
| ROX | 40, 42, 43, 53, 73, 82 | |
| CY5 | Taolo ea Ka Hare |
Li-parameter tsa Tekheniki
| Polokelo | Metsi: ≤-18℃ |
| Nako ea ho phela | Likhoeli tse 12 |
| Mofuta oa Sampole | Sesepa sa molomo oa popelo, Sesepa sa botšehali, moroto |
| Ct | ≤28 |
| CV | <5.0% |
| LoD | Likopi tse 300/mL |
| Lisebelisoa tse Sebetsang | Mekhoa ea Li-biosystem tse Sebelisitsoeng 7500 Mekhoa ea PCR ea Nako ea Sebele Mekhoa ea PCR e Potlakileng ea Li-Biosystem tse 7500 tsa Nako ea 'Nete QuantStudio®Mekhoa e 5 ea PCR ea Nako ea Sebele Mekhoa ea PCR ea Nako ea Sebele ea SLAN-96P Leseli la ho Tsamaisa Li-Cycler®Sistimi ea PCR ea Nako ea 'Nete ea 480 Sistimi ea ho lemoha PCR ea LineGene 9600 Plus ea Nako ea 'Nete MA-6000 Nako ea Sebele ea Bongata ba Thermal Cycler Sistimi ea PCR ea BioRad CFX96 ea Nako ea 'Nete Sistimi ea PCR ea BioRad CFX Opus 96 ea Nako ea 'Nete |
Phallo ea Mosebetsi
Sheba Kit ea IFU bakeng sa lintlha tse qaqileng
Tharollo ea 1 (Ho ntšoa ha nucleic acid ka boiketsetso)
Tharollo ea 2: (Sesebelisoa sa ho Lokolla Sampole ea Macro le Micro-Test)
Li-reagent lia hlokahala empa ha lia fanoa
Sesebediswa sa ho Lokolla Sample Release Reagent sa Macro & Micro-Test (HWTS-3005-8), Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (e ka sebediswang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) ke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).
Lintho tse sebelisoang lia hlokahala empa ha lia fanoa
Li-tube tsa centrifuge tsa DNase/RNase tse se nang 1.5mL, Malebela a DNase/RNase a se nang DNase, 0.2mL ea li-tube tsa PCR, centrifuge ea desktop, motsoako oa ho sisinyeha ha desktop.