Mefuta e 28 ea Kotsi e Phahameng ea Papilloma Virus ea Motho (Typing ea 16/18) Nucleic Acid

Tlhaloso e Khutšoanyane:

Sesebelisoa sena se loketse ho lemoha boleng ba in vitro mefuta e 28 ea livaerase tsa papilloma ea motho (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52.HPV 16/18 e ka thaepa, mefuta e setseng e ke ke ea ngoloa ka ho feletseng, ho fana ka mokhoa o thusang bakeng sa tlhahlobo le phekolo ea tšoaetso ea HPV.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-CC006A-28 Mefuta ea Kotsi e Phahameng ea Papilloma Virus ea Motho (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Kankere ea popelo ke e 'ngoe ea lihlahala tse kotsi tse atileng ka ho fetesisa tsa pampitšana ea pelehi ea mosali.Liphuputso li bontšitse hore tšoaetso ea HPV e phehellang le mafu a mangata ke e 'ngoe ea lisosa tse ka sehloohong tsa mofetše oa molomo oa popelo.Hajoale, liphekolo tse lemohuoeng tse sebetsang hantle li ntse li haella bakeng sa mofetše oa popelo o bakoang ke HPV, kahoo ho sibolloa kapele le thibelo ea tšoaetso ea molomo oa popelo e bakoang ke HPV ke senotlolo sa ho thibela mofetše oa popelo.Ho bohlokoa haholo ho theha tlhahlobo e bonolo, e tobileng le e potlakileng ea tlhahlobo ea etiology bakeng sa tlhahlobo ea bongaka le kalafo ea mofetše oa popelo.

Channel

Reaction Mix Channel Mofuta
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Taolo ea ka hare
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Taolo ea ka hare

Tekheniki Parameters

Polokelo Mokelikeli: ≤-18℃
Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala Motsoako oa Cervical Swab, Vaginal Swab, Moroto
Ct ≤28
CV <5.0%
LoD 300Likopi / mL
Lisebelisoa tse sebetsang Applied Biosystems 7500 Real-Time PCR Systems
Applied Biosystems 7500 Fast Real-Time PCR Systems
QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR
Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P
LightCycler®Sistimi ea 480 ea Nako ea 'Nete ea PCR
LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi
MA-6000 Real-Nako Quantitative Thermal Cycler
Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96
BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

Sehlahisoa se khothalelitsoeng: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (e ka sebelisoang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Kenya 200μL ea letsoai le tloaelehileng ho emisa pellet mohatong oa 2.1, ebe ho ntšoa ho lokela ho etsoa ho latela ho litaelo tsa tšebeliso ea reagent ena ea ho ntša.Molumo o khothaletsoang oa elution ke 80μL.
Sehlahisoa se khothalelitsoeng: QIAamp DNA Mini Kit (51304) kapa Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Eketsa 200μL ea letsoai le tloaelehileng ho emisa pellet mohatong oa 2.1, 'me joale ho ntšoa ho lokela ho etsoa ho latela litaelo tsa tšebeliso ea reagent ena.Bolumo ea sampole e nkiloeng ea lisampole kaofela ke 200μL, 'me bophahamo ba molumo o khothaletsoang ke 100μL.