Staphylococcus Aureus le Methicillin-Resistant Staphylococcus Aureus (MRSA/SA)

Tlhaloso e Khutšoanyane:

Setsi sena se sebelisetsoa ho lemoha boemo ba staphylococcus aureus le li-staphylococcus aureus nucleic acid tse hanyetsanang le methicillin ka lisampole tsa sekhohlela sa motho, lisampole tsa nko le lisampole tsa tšoaetso ea letlalo le lisele tse bonolo ka har'a vitro.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-OT062 Staphylococcus Aureus le Methicillin-Resistant Staphylococcus Aureus (MRSA/SA) Nucleic Acid Detection Kit(Fluorescence PCR)

Setifikeiti

CE

Epidemiology

Staphylococcus aureus ke e 'ngoe ea libaktheria tsa bohlokoa tsa pathogenic tsa nosocomial.Staphylococcus aureus (SA) ke ea staphylococcus 'me ke moemeli oa baktheria ea Gram-positive, e ka hlahisang mefuta e mengata ea chefo le li-enzyme tse hlaselang.Libaktheria li na le litšobotsi tsa ho ajoa ka bophara, pathogenicity e matla le sekhahla se phahameng sa ho hanyetsa.Thermostable nuclease gene (nuc) ke mofuta o bolokehileng haholo oa staphylococcus aureus.

Channel

FAM Lefutso la mecA le hananang le methicillin
ROX

Taolo ea ka hare

CY5 staphylococcus aureus nuc gene

Tekheniki Parameters

Polokelo ≤-18℃ & e sirelelitsoe khanyeng
Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala sekhohlela, disampole tsa tshwaetso ya letlalo le dithishu tse bonolo, le disampole tsa swab ya nko
Ct ≤36
CV ≤5.0%
LoD 1000 CFU/mL staphylococcus aureus, 1000 CFU/mL libaktheria tse hanyetsanang le methicillin.Ha khiti e lemoha tšupiso ea naha ea LoD, 1000/mL staphylococcus aureus e ka bonoa.
Tse khethehileng Teko e nang le litefo e bonts'a hore ke tlokotsi ena e be le tšusumetso ea li-pathoges tse ling tse ntle tse nang le limela, li-ascherichi li hatella. , Proteus mirabilis, enterobacter cloacae, streptococcus pneumoniae, enterococcus faecium, candida albicans, legionella pneumophila, candida parapsilosis, moraxella catarrhalis, neisseria meningitidis, haemophilus influenzae.
Lisebelisoa tse sebetsang Applied Biosystems 7500 Real-Time PCR Systems

QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR

Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P

LightCycler®Sistimi ea 480 ea Nako ea 'Nete ea PCR

LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi

MA-6000 Real-Nako Quantitative Thermal Cycler

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

Khetho ea 1.

Macro & Micro-Test Genomic DNA/RNA Kit (HWTS-3019) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. e ka sebelisoa le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS- 3006B).Eketsa 200µL ea saline e tloaelehileng ho pula e sebelitsoeng, 'me mehato e latelang e lokela ho ntšoa ho ea ka litaelo,' me bophahamo ba molumo o khothaletsoang ke 80µL.

Khetho ea 2.

Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Kenya 1mL ea saline e tloaelehileng ho metsi ka mor'a ho hlatsoa ka saline e tloaelehileng, ebe u kopanya hantle.Centrifuge ho 13,000r/min bakeng sa metsotso e 5, tlosa supernatant (boloka 10-20µL ea supernatant), 'me u latele litaelo bakeng sa ho ntšoa ho latelang.

Sehlahisoa se khothalelitsoeng sa ho ntšoa: Nucleic Acid Extraction kapa Purification Reagent (YDP302) ke Tiangen Biotech (Beijing) Co.,Ltd.Ho ntšoa ho lokela ho etsoa ka tieo ho latela mohato oa 2 oa bukana ea litaelo.Ho khothaletsoa ho sebelisa metsi a se nang RNase le a DNase bakeng sa tlhahiso ea molumo oa 100µL.

 


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona