Pathogen e supileng ea Urogenital

Tlhaloso e Khutšoanyane:

Setsi sena se sebelisetsoa ho lemoha boleng ba chlamydia trachomatis (CT), neisseria gonorrhoeae (NG) le mycoplasma genitalium (MG), mycoplasma hominis (MH), herpes simplex virus mofuta oa 2 (HSV2), ureaplasma parvum (UP) le ureaplasma urealyticum. (UU) li-nucleic acid ho li-swabs tsa banna le lisampole tsa cervical swab in vitro, bakeng sa ho thusa ho hlahloba le ho phekola bakuli ba nang le tšoaetso ea genitourinary tract.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-UR017A Seven Urogenital Pathogen Nucleic Acid Detection Kit(Melting Curve)

Epidemiology

Mafu a tšoaetsanoang ka thobalano (STDs) e ntse e le e 'ngoe ea litšokelo tsa bohlokoa ho ts'ireletseho ea bophelo bo botle ba sechaba lefatšeng ka bophara, e ka lebisang ho nyopa, ho hlaha pele ho nako, lihlahala le mathata a fapaneng a tebileng.Likokoana-hloko tse tloaelehileng li kenyelletsa chlamydia trachomatis, neisseria gonorrhoeae, mycoplasma genitalium, mycoplasma hominis, herpes simplex virus mofuta oa 2, ureaplasma parvum, le ureaplasma urealyticum.

Channel

FAM CT le NG
HEX MG, MH le HSV2
ROX

Taolo ea ka hare

Tekheniki Parameters

Polokelo

≤-18℃

Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala mafu a urethral

Li-secretions tsa cervical

Tt ≤28
CV ≤5.0%
LoD CT: 500Copies/mL

NG: 400Likopi/mL

MG:1000Likopi/mL

MH: 1000Likopi/mL

HSV2:400Likopi/mL

HO HLOKA:500Copies/mL

UU:500Copies/mL

Tse khethehileng Lekola likokoana-hloko tse tšoaelitsoeng ka ntle ho sebaka sa ho lemoha ha lisebelisoa tsa tlhahlobo, tse kang treponema pallidum, candida albicans, trichomonas vaginalis, staphylococcus epidermidis, escherichia coli, gardnerella vaginalis, adenovirus, cytomegalovirus, beta Streptococcus human gecinome, HIV, le HIV.'Me ha ho na cross-reactivity.

Matla a khahlanong le tšitiso: 0.2 mg/mL bilirubin, mamina a molomo oa popelo, 106lisele/mL lisele tse tšoeu tsa mali, 60 mg/mL mucin, mali a feletseng, peo ea botona, lithethefatsi tse atisang ho sebelisoa antifungal (200 mg/mL levofloxacin, 300 mg/mL erythromycin, 500 mg/mL penicillin, 300mg/mL azithromycin, 10% Jieeryin lotion , 5% Fuyanjie lotion) u se ke ua kena-kenana le kit.

Lisebelisoa tse sebetsang Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P

Sesebelisoa sa PCR sa LightCycler®480 Real-Time

Phallo ea Mosebetsi

Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).

A) Mokhoa oa matsoho: Nka 1.5mL DNase / RNase-free centrifuge tube 'me u kenye 200μL ea sampuli ho hlahlojoa.Mehato e latelang e lokela ho ntšoa ka mokhoa o tiileng oa IFU.Molumo o khothaletsoang oa elution ke 80μL.

B) Mokhoa o ikemetseng: Nka sephutheloana sa ho hula se pakiloeng esale pele, eketsa 200 μL ea sampole hore e lekoe sebakeng se lumellanang sa seliba, 'me mehato e latelang e lokela ho ntšoa ho latela IFU.


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona