Clostridium difficile toxin A/B gene (C.diff)

Tlhaloso e Khutšoanyane:

Setsi sena se reretsoe ho lemoha boleng ba "clostridium difficile toxin A" le mofuta oa chefo ea B ka lisampole tsa mantle ho tsoa ho bakuli ba belaelloang hore ba na le tšoaetso ea clostridium difficile.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-OT031A Nucleic Acid Detection Kit for Clostridium difficile toxin A/B gene (C.diff) (Fluorescence PCR)

Setifikeiti

CE

Epidemiology

Clostridium difficile (CD), gram-positive anaerobic sporogenic Clostridium difficile, ke e 'ngoe ea likokoana-hloko tse ka sehloohong tse bakang mafu a nosocomial mala.Ho ea ka meriana, hoo e ka bang 15% ~ 25% ea letšollo le amanang le likokoana-hloko, 50% ~ 75% ea lefu la ho ruruha le amanang le likokoana-hloko le 95% ~ 100% ea pseudomembranous enteritis e bakoa ke tšoaetso ea Clostridium difficile (CDI).Clostridium difficile ke pathogen e nang le maemo, ho kenyelletsa le mefuta e nang le chefo le mefuta e seng ea toxigenic.

Channel

FAM tcdAlefutso
ROX tcdBlefutso
VIC/HEX Taolo ea ka hare

Tekheniki Parameters

Polokelo

≤-18℃

Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala setuloana
Tt ≤38
CV ≤5.0%
LoD 200CFU/mL
Tse khethehileng sebelisa setlolo sena ho lemoha likokoana-hloko tse ling tsa mala tse kang Escherichia coli, Staphylococcus aureus, Shigella, Salmonella, Vibrio parahaemolyticus, Sehlopha sa B Streptococcus, Clostridium difficile mefuta e seng ea pathogenic, Adenovirus, rotavirus, norovirus, kokoana-hloko ea ntaramane, le ntaramane. DNA, liphetho kaofela li mpe.
Lisebelisoa tse sebetsang Applied Biosystems 7500 Real-Time PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR

SLAN-96P ea Nako ea Sebele PCR Systems (Hongshi Medical Technology Co., Ltd.)

LightCycler®Sistimi ea 480 ea Nako ea 'Nete ea PCR

LineGene 9600 Plus Nako ea 'Nete ea PCR Detection System(FQD-96A,HangzhouTheknoloji ea bioer)

MA-6000 Nako ea 'Nete ea Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

Khetho ea 1.

Kenya 180μL ea lysozyme buffer ho precipitate (hlapolla lysozyme ho 20mg/mL ka lysozyme diluent), pipette ho kopanya hantle, le ho sebetsa ka 37 ° C ka metsotso e fetang 30. Nka 1.5mL ea RNase / DNase-free centrifuge tube, le ho eketsa180μL ea taolo e ntle le taolo e mpe ka tatellano.Eketsa10μL ea taolo ea ka hare ho sampole e tla lekoa, taolo e nepahetseng, le taolo e mpe ka tatellano, le ho sebelisa Nucleic Acid Extraction kapa Purification Reagent (YDP302) ke Tiangen Biotech (Beijing) Co., Ltd. ka kopo latela ka tieo litaelo tsa tšebeliso bakeng sa mehato e itseng.Sebelisa DNase/RNase mahala H2O bakeng sa elution, 'me bophahamo ba modumo o khothaletsoang ke 100μL.

Khetho ea 2.

Nka 1.5mL ea RNase/DNase-free centrifuge tube, 'me u kenye 200μL ea taolo e ntle le taolo e mpe ka tatellano.Eketsa10μL ea taolo ea kahare ho sampole e tla lekoa, taolo e nepahetseng, le taolo e mpe ka tatellano, le ho sebelisa Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004- 96) le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006).Ho ntšoa ho lokela ho etsoa ho latela litaelo tsa tšebeliso, 'me bophahamo ba molumo o khothaletsoang ke 80μL.

 