Mycoplasma Genitalium (Mg)

Tlhaloso e Khutšoanyane:

Setsi sena se sebelisetsoa ho lemoha boleng ba in vitro ea Mycoplasma genitalium (Mg) nucleic acid ka har'a pampitšana ea moroto oa banna le secretions ea setho sa botšehali.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-UR014A Mycoplasma Genitalium (Mg) Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Mafu a tšoaetsanoang ka thobalano (STD) e ntse e le e 'ngoe ea litšokelo tse kholo ho ts'ireletso ea bophelo bo botle ba sechaba lefatšeng ka bophara, e ka lebisang ho nyopa, tsoalo ea pele ho nako, tumorigenesis, le mathata a fapaneng a tebileng [1-4].Ho na le mefuta e mengata ea mafu a likobo, ho kenyelletsa libaktheria, livaerase, chlamydia, mycoplasma le spirochetes.Mefuta e tloaelehileng e kenyelletsa Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum, Herpes simplex virus type 1, Herpes simplex virus type 2, Mycoplasma hominis, Mycoplasma genitalium joalo-joalo.

Channel

FAM Mg
ROX

Taolo ea ka hare

Tekheniki Parameters

Polokelo

-18℃

Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala utlhahiso ea rethral,mafu a molomo oa popelo
Tt ≤38
CV ≤5.0%
LoD 500 Likopi / μL
Tse khethehileng Ha ho na ts'ebetso ea ho kopana le likokoana-hloko tse ling tsa mafu a tšoaetsanoang ka thobalano, joalo ka Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Mycoplasma hominis, Herpes simplex virus type 1, le Herpes simplex virus mofuta oa 2.
Lisebelisoa tse sebetsang Applied Biosystems 7500 Real-Time PCR SystemsQuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR

Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P

LightCycler®Sistimi ea 480 ea Nako ea 'Nete ea PCR

LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi

MA-6000 Real-Nako Quantitative Thermal Cycler

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96

BioRad CFX Opus 96 Real-Nako PCR System

Phallo ea Mosebetsi

Khetho ea 1.

Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), e lokela ho ntšoaka tieoho latela litaelo.

Khetho ea 2.

Macro& Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS -3006C), e lokela ho ntšoa ka thata ho latela litaelo.Molumo o khothaletsoang oa elution ke 80µL.

Khetho3.

Nucleic Acid Extraction kapa Purification Kit(YDP302)e entsoeng ke Tiangen Biotech (Beijing) Co., Ltd., e lokela ho ntšoa ho latela litaelo tse tiileng.Molumo o khothaletsoang oa elution ke 80µL.