Mycoplasma Genitalium (Mg)

Tlhaloso e Khutšoanyane:

Sete ena e sebelisetsoa ho lemoha Mycoplasma genitalium (Mg) nucleic acid ka hare ho vitro ka har'a moroto oa banna le ka har'a moroto oa basali.


Qaqiso ea Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

Kiti ea ho lemoha acid ea nucleic ea HWTS-UR014A Mycoplasma Genitalium (Mg) (Fluorescence PCR)

Thuto ea mafu a seoa

Mafu a tšoaetsanoang ka thobalano (STD) e ntse e le e 'ngoe ea litšokelo tse kholo ts'ireletsong ea bophelo bo botle ba sechaba lefatšeng ka bophara, e leng se ka lebisang ho hloleheng ha ho ba le bana, tsoalo ea pele ho nako, ho hlaha ha hlahala, le mathata a fapaneng a tebileng [1-4]. Ho na le mefuta e mengata ea likokoana-hloko tsa STD, ho kenyeletsoa libaktheria, livaerase, chlamydia, mycoplasma, le spirochetes. Mefuta e tloaelehileng e kenyelletsa Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum, Herpes simplex virus type 1, Herpes simplex virus type 2, Mycoplasma hominis, Mycoplasma genitalium le jj.

Mokero

FAM Mg
ROX

Taolo ea Ka Hare

Li-parameter tsa Tekheniki

Polokelo

-18℃

Nako ea ho phela Likhoeli tse 12
Mofuta oa Sampole uho ntšoa ha rethra,maro a molomo oa popelo
Tt ≤38
CV ≤5.0%
LoD Likopi tse 500/μL
Ho hlaka Ha ho na karabelo e kopanang le dikokwana-hloko tse ding tsa mafu a tshwaetsanang ka thobalano, tse kang Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Mycoplasma hominis, Herpes simplex virus type 1, le Herpes simplex virus type 2.
Lisebelisoa tse Sebetsang Mekhoa ea Li-biosystem tse Sebelisitsoeng 7500 Mekhoa ea PCR ea Nako ea SebeleQuantStudio®Mekhoa e 5 ea PCR ea Nako ea Sebele

Mekhoa ea PCR ea Nako ea Sebele ea SLAN-96P

Leseli la ho Tsamaisa Li-Cycler®Sistimi ea PCR ea Nako ea 'Nete ea 480

Sistimi ea ho lemoha PCR ea LineGene 9600 Plus ea Nako ea 'Nete

MA-6000 Nako ea Sebele ea Bongata ba Thermal Cycler

Sistimi ea PCR ea BioRad CFX96 ea Nako ea 'Nete

Sistimi ea PCR ea BioRad CFX Opus 96 ea Nako ea 'Nete

Phallo ea Mosebetsi

Khetho ea 1.

Setlolo sa ho Lokolla Sample Release Reagent sa Macro le Micro-Test (HWTS-3005-8), se lokela ho ntšoaka tieoho latela litaelo.

Khetho ea 2.

Seteishene sa DNA/RNA se Akaretsang sa Macro&Micro-Test (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS-3006C), se lokela ho ntšoa ka tieo ho latela litaelo. Bophahamo bo khothaletsoang ba elution ke 80µL.

Khetho3.

Sete ea ho Ntša kapa ho Hloekisa Nucleic Acid(YDP302)e hlahisitsoeng ke Tiangen Biotech (Beijing) Co., Ltd., e lokela ho ntšoa ho latela litaelo ka tieo. Bophahamo bo khothaletsoang ba elution ke 80µL.


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa oa hau mona 'me u o romelle ho rona