Herpes Simplex Virus Type 2 Nucleic Acid
Lebitso la Sehlahiswa
HWTS-UR007A-Herpes Simplex Virus Type 2 Nucleic Acid Detection Kit (Fluorescence PCR)
Tšebeliso e reriloeng
Setsi sena se sebelisetsoa ho lemoha boleng ba herpes simplex kokoana-hloko ea mofuta oa 2 nucleic acid ho banna ba urethral swab le lisampole tsa cervical swab.
Epidemiology
Herpes Simplex Virus Type 2 (HSV2) ke kokoana-hloko e selikalikoe e entsoeng ka tegument, capsid, core, le enfelopo, 'me e na le DNA ea mela e habeli.kokoana-hloko ea Herpes e ka kena 'meleng ka ho kopana ka ho toba kapa ho kopanela liphate le letlalo le li-membrane tsa mucous,' me e arotsoe ka sehloohong le se tloaelehileng.Tšoaetso ea kokoana-hloko e bakoa haholo ke HSV2, bakuli ba banna ba bonahatsoa e le liso tsa botona, 'me bakuli ba basali ba bonahatsoa e le liso tsa molomo, vulvar le botšehali.Tšoaetso ea pele ea kokoana-hloko ea genital herpes hangata ke ts'oaetso e feteletseng, ntle le likokoana-hloko tse seng kae tsa lehae tse nang le lera kapa letlalo, tseo bongata ba tsona li se nang matšoao a hlakileng a kliniki.Genital herpes tšoaetso e na le litšobotsi tsa bophelo bohle ba kokoana-hloko e jereng le ho ipheta habonolo, 'me bakuli ka bobeli le bajari ke mohloli oa tšoaetso ea lefu lena.Chaena, sekhahla sa serological positive sa HSV2 se ka ba 10.80% ho isa ho 23.56%.Mokhahlelo oa tšoaetso ea HSV2 o ka aroloa ka ts'oaetso ea mantlha le ts'oaetso ea khafetsa, 'me hoo e ka bang 60% ea bakuli ba nang le tšoaetso ea HSV2 ba khutlela mokhoeng oo.
Epidemiology
FAM: Herpes Simplex Virus Type 2 (HSV2)·
VIC(HEX): Taolo ea ka hare
PCR Amplification Conditions Setting
Mohato | Lipotoloho | Mocheso | Nako | BokellaFluorescentSli-ignalskapa eseng joalo |
1 | 1 potoloho | 50 ℃ | 5 mets | No |
2 | 1 potoloho | 95℃ | 10metsotso | No |
3 | 40 Lipotoloho | 95℃ | 15secs | No |
4 | 58℃ | 31secs | Ee |
Tekheniki Parameters
Polokelo | |
Mokelikeli | ≤-18℃ Lefifing |
Shelf-bophelo | Likhoeli tse 12 |
Mofuta oa Mohlala | Sekoti sa molomo oa popelo sa mosali, Sesepa sa botona |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 50Likopi/karabelo |
Tse khethehileng | Ha ho na cross-reactivity le likokoana-hloko tse ling tsa STD, tse kang Treponema pallidum, Chlamydia trachomatis, Ureaplasma urealyticum, Mycoplasma hominis, Mycoplasma genitalium joalo-joalo. |
Lisebelisoa tse sebetsang | E ka tsamaisana le lisebelisoa tsa PCR tsa fluorescent tse fumanehang 'marakeng. Applied Biosystems 7500 Real-Time PCR Systems Applied Biosystems 7500 Fast Real-Time PCR Systems QuantStudio®5 Nako ea 'Nete ea PCR Systems Litsamaiso tsa PCR tsa nako ea sebele tsa SLAN-96P Sesebelisoa sa PCR sa LightCycler®480 Real-Time LineGene 9600 Plus Nako ea 'Nete ea PCR ea ho Fumana Sistimi MA-6000 Real-Nako Quantitative Thermal Cycler Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96 BioRad CFX Opus 96 Real-Nako PCR System. |