Gardnerella Vaginalis Nucleic Acid
Lebitso la sehlahisoa
HWTS-UR042-Gardnerella Vaginalis Nucleic Acid Detection Kit(Fluorescence PCR)
Epidemiology
Sesosa se tloaelehileng sa vaginitis ho basali ke bacterial vaginosis, 'me baktheria ea bohlokoa ea pathogenic ea baktheria vaginosis ke Gardnerella vaginalis. Gardnerella vaginalis (GV) ke pathogen e nkang monyetla e sa bakeng mafu ha e le teng ka bongata. Leha ho le joalo, ha baktheria e ka sehloohong ea Lactobacilli e fokotsehile kapa e felisoa, e baka ho se leka-lekane tikolohong ea botšehali, Gardnerella vaginalis e ata ka bongata, e lebisang ho bacterial vaginosis. Ka nako e ts'oanang, likokoana-hloko tse ling (tse kang Candida, Neisseria gonorrhoeae, Chlamydia trachomatis, joalo-joalo) li atisa ho hlasela 'mele oa motho, ho baka vaginitis e tsoakiloeng le cervicitis. Haeba vaginitis le cervicitis li sa fumanoe le ho phekoloa ka nako e nepahetseng, ho ka 'na ha e-ba le tšoaetso e ntseng e phahama ke likokoana-hloko ka har'a mucosa ea "reproductive tract", e lebisang habonolo ho mafu a holimo a kang endometritis, salpingitis, abscess ea tubo-ovarian (TOA), le pelvic peritonitis, e ka lebisang ho boima bo tebileng le ho ima. liphetho.
Tekheniki Parameters
Polokelo | -18℃ |
Shelf-bophelo | Likhoeli tse 12 |
Mofuta oa Mohlala | li-swabs tsa monna, li-swabs tsa popelo ea mosali, lesela la botšehali la mosali |
Ct | ≤38 |
CV | 5.0% |
LoD | 400 Likopi / mL |
Lisebelisoa tse sebetsang | E sebetsa ho mochini oa ho lemoha oa mofuta oa I:Applied Biosystems 7500 Real-Nako PCR Systems, QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR, SLAN-96P ea Nako ea Sebele PCR Systems (Hongshi Medical Technology Co., Ltd.), LineGene 9600 Plus Nako ea 'Nete ea PCR Detection Systems (FQD-96A, theknoloji ea Hangzhou Bioer), MA-6000 Real-Nako Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96, BioRad CFX Opus 96 Real-Nako PCR System. E sebetsa ho mofuta oa II reagent ea ho lemoha: EudemonTMAIO800 (HWTS-EQ007) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Phallo ea Mosebetsi
Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (e ka sebelisoang ka Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), le Macro & Micro-Test Viral DNA/RNA Kit (HWTS-80) e sebelisa EWTS-30TM AIO800 (HWTS-EQ007)) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Bolumo ea sampole e ntšitsoeng ke 200μL mme bophahamo ba molumo o khothaletsoang ke 150μL.