Chlamydia Trachomatis, Neisseria Gonorrhoeae le Trichomonas vaginalis

Tlhaloso e Khutšoanyane:

Sete ena e etselitsoe ho lemoha Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) ka hare ho vitro.leTrichomonal vaginitis (TV) ka hara swab ya urethral ya banna, swab ya molomo wa popelo ya basadi, le disampole tsa swab ya botšehali ya basadi, mme e thusa ho hlahloba le ho phekola bakudi ba nang le ditshwaetso tsa tsamaiso ya genitourinary.


Qaqiso ea Sehlahisoa

Li-tag tsa Sehlahisoa

Lebitso la sehlahisoa

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae le Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)

Thuto ea mafu a seoa

Chlamydia trachomatis (CT) ke mofuta oa likokoana-hloko tsa prokaryotic tse nang le likokoana-hloko liseleng tsa eukaryotic feela. Chlamydia trachomatis e arotsoe ka li-serotype tsa AK ho latela mokhoa oa serotype. Litšoaetso tsa mokhoa oa urogenital li bakoa haholo ke li-serotype tsa DK tse fapaneng tsa trachoma, 'me banna ba iponahatsa haholo e le urethritis, e ka fokotsoang ntle le kalafo, empa boholo ba tsona li fetoha tse sa foleng, li mpefala nako le nako, 'me li ka kopanngoa le epididymitis, proctitis, jj.

Mokero

FAM Chlamydia trachomatis
ROX Neisseria gonorrhoeae
CY5 Bofuma ba Trichomonal
VIC/HEX Taolo ea Ka Hare

Li-parameter tsa Tekheniki

Polokelo

-18℃

Nako ea ho phela Likhoeli tse 12
Mofuta oa Sampole Swab ea molomo oa popelo ea mosali,Sesepa sa botšehali sa basali,Sesepa sa urethra sa banna
Ct ≤38
CV <5%
LoD 400Likopi/mL
Ho hlaka Ha ho na karabelo e kopanang le dikokwana-hloko tse ding tsa tshwaetso ya STD ka ntle ho sebaka sa ho lemoha sa kit ya teko, jwalo ka Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, jj.
Lisebelisoa tse Sebetsang Sistimi ea PCR ea Nako ea 'Nete e Sebelisitsoeng ea 7500

Mekhoa ea PCR e Potlakileng ea Li-Biosystem tse 7500 tsa Nako ea 'Nete

QuantStudio®Mekhoa e 5 ea PCR ea Nako ea Sebele

Mekhoa ea PCR ea Nako ea Sebele ea SLAN-96P

Leseli la ho Tsamaisa Li-Cycler®Sistimi ea PCR ea Nako ea 'Nete ea 480

Sistimi ea ho lemoha PCR ea LineGene 9600 Plus ea Nako ea 'Nete

MA-6000 Nako ea Sebele ea Bongata ba Thermal Cycler

Sistimi ea PCR ea BioRad CFX96 ea Nako ea 'Nete

Sistimi ea PCR ea BioRad CFX Opus 96 ea Nako ea 'Nete

Phallo ea Mosebetsi

Khetho ea 1.

Reagent e kgothalletswang ya ho ntsha: Pipette 1mL ya sampole e tla lekoa ho 1.5mL ya tube ya centrifuge e se nang DNase/RNase, centrifuge ka 12000rpm metsotso e 3, lahla supernatant mme o boloke precipitate. Kenya 200µL ya saline e tlwaelehileng ho precipitate ho tswela pele ho tshwarwa. Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (e ka sebediswang le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) ke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ho ntshwa ho lokela ho etswa ho ya ka ditaelo tsa tshebediso. Bophahamo ba sampole e ntshitsweng ke 200µL, mme bophahamo bo kgothaletswang ba elution ke 80µL.

Khetho ea 2.

Setlolo se kgothaletswang sa ho ntsha: Nucleic Acid Extraction kapa Purification Kit (YDP302). Ho ntsha ho lokela ho etswa ka thata ho ya ka ditaelo tsa tshebediso. Bophahamo bo kgothaletswang ba elution ke 80µL.


  • E fetileng:
  • E 'ngoe: