HWTS-OT018-Bacillus Anthracis Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Bacillus anthracis ke baktheria ea gram-positive spore-forming e khonang ho baka boloetse bo tšoaetsanoang bo matla ba zoonotic, koatsi. Ho ea ka litsela tse sa tšoaneng tsa tšoaetso, koatsi e arotsoe ka koatsi ea letlalo, koatsi ea mala le koatsi ea matšoafo. Koatsi e hlabang ke eona e atileng haholo, haholo hobane ho kopana ha motho le boea le nama ea liphoofolo tse ruiloeng e tšoaelitsoeng ke bacillus anthracis. E na le sekhahla se tlase sa ho shoa 'me e ka phekoloa ka ho feletseng kapa esita le ho ipholisa. Batho ba ka boela ba tšoaetsoa ke koatsi ea matšoafo ka tsela ea phefumoloho, kapa ba ja nama ea liphoofolo tse ruiloeng e nang le koatsi hore e tšoaetsoe ke koatsi ea mala. Tšoaetso e matla e ka baka meningitis ea koatsi esita le lefu. Hobane li-spores tsa bacillus anthracis li na le khanyetso e matla ho tikoloho e ka ntle, haeba seoa se ke ke sa fumanoa le ho sebetsanoa ka nako, libaktheria tsa pathogenic li tla lokolloa tikolohong ka moeti ho etsa li-spores hape, ho etsa potoloho ea tšoaetso, ho beha tšoso ea nako e telele sebakeng seo.

Tekheniki Parameters

Polokelo

≤-18℃

Shelf-bophelo Likhoeli tse 12
Mofuta oa Mohlala mali, lymph fluid, isolates cultured le mehlala e meng
CV ≤5.0%
LoD Likopi tse 5/μL
Lisebelisoa tse sebetsang E sebetsa ho mochini oa ho lemoha oa mofuta oa I:

Applied Biosystems 7500 Real-Nako PCR Systems,

QuantStudio®Litsamaiso tse 5 tsa nako ea 'nete tsa PCR,

SLAN-96P ea Nako ea Sebele PCR Systems (Hongshi Medical Technology Co., Ltd.),

LineGene 9600 Plus ea Nako ea 'Nete ea PCR Detection Systems (FQD-96A,Theknoloji ea Hangzhou Bioer),

MA-6000 Real-Nako Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.),

Sistimi ea PCR ea Nako ea 'Nete ea BioRad CFX96,

BioRad CFX Opus 96 Real-Nako PCR System.

E sebetsa ho mofuta oa II reagent ea ho lemoha:

EudemonTMAIO800 (HWTS-EQ007) ka Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

 

Phallo ea Mosebetsi

Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) le Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-Macsu6BTS & 3 Jisu6BTS) Med-Tech Co., Ltd. Ho ntšoa ho lokela ho etsoa ho latela IFU ka tieo. Molumo o khothaletsoang oa elution ke 80μL.